Baxi Eco 4 S 24 kW Kombi
Orders are accepted via WhatsApp
Maximum useful heating capacity kW: 24
Minimum useful heating capacity kW: 9.3
Maximum consumption heat capacity kW: 25.8
Minimum consumption heat capacity kW: 10.6
Maximum productivity (Useful efficiency): % 92.9
Capacity/expansion tank filling pressure l/bar 6/0.8
Combustion chamber: closed
Temperature adjustment range in the IST contour: °С 35-60
Productivity of hot water under ΔТ=25°С l/min: 13.7
Minimum water consumption in the hot water supply (HT) circuit l/min 2
Maximum pressure in the IST circuit bar: 8
Minimum pressure bar in the IST circuit: 0.15
Diameter of smoke pipes (coax./separator) mm: 60-100/80
Maximum length of smoke pipes (coax/separator): м 5/30
Nominal inlet pressure of natural gas: 13-20 mbar
Power/voltage W/V: 130/230
Country of manufacture: Italy
– height: mm 730 730
– width mm: 400 400
– depth: mm 299 299
Net weight: kg 30/33 26/29
Continuous electronic modulation of the flame in heating and hot water supply modes;
Smooth electronic ignition;
The boilers are adapted to the natural conditions of the territory of Azerbaijan. They work continuously when the inlet pressure of natural gas decreases to 5 mbar;
The flame separators in the fireplace are made of stainless steel;
Patented air supply regulation system (models with a closed chamber);
It can be retrofitted to run on LPG.
Hydraulic group from composite materials;
Hot water flow transmission pipe flow meter;
Primary copper heat exchanger coated with a special composition for additional protection against corrosion;
Second stainless steel plate heat exchanger;
Three-way valve with electric servo drive;
Energy-saving circulation pump with built-in automatic water separator;
Manometer;
Automatic cycle;
Postcirculation of the pump;
Cold water inlet filter;
The possibility of connecting an external collector boiler for hot water;
Ability to connect to solar collectors.
Two temperature adjustment ranges in the heating system: 30-85 оС and 30-45 оС ("warm floors" mode);
Built-in weather-dependent automation (possibility of connecting a temperature sensor on the street);
Regulation and automatic maintenance of the given temperature in the heating and hot water supply circuit;
Temperature digital timer;
The possibility of connecting a room thermostat and a programmable time setting device;
Control and security devices;
Antifreeze protection system in heating and hot water supply circuits.
The ability to send a signal to the dispatcher's remote control device about blocking the boiler;
Aluminum ionizing control;
Pump blocking system (starts automatically every 24 hours);
Anti-lock protection system of the three-inlet valve (automatically activates every 24 hours);
Water overheating protection thermostat in the primary heat exchanger;
Traction force device for controlling the safe removal of combustion products (pneumorela for models with a closed combustion chamber, thermostat for models with an open chamber);
Pressostat in the heating system — turns on when the water pressure is insufficient;
Safety valve in the heating circuit (3 atm.);